Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Arq. bras. neurocir ; 38(1): 7-11, 15/03/2019.
Article in English | LILACS | ID: biblio-1362609

ABSTRACT

Objective To analyze 78 cases of brachial plexus injury submitted to the Oberlin technique between 2003 and 2012. The potential complications of this technique were analyzed, especially motor damage or hypoesthesia of the hand. Method Medical records from patients with brachial plexus injuries at the levels of the C5-C6 and C5-C6-C7 vertebrae were retrospectively analyzed. Cases submitted to the Oberlin procedure with or without concomitant brachial plexus procedures between 2003 and 2012 were evaluated. The minimum follow-up period was of 1 year. In addition to the clinical examination, electromyography and magnetic resonance imaging (MRI) of the brachial plexus were used to diagnose and locate the nerve damage. Results A total of 78 surgical patients met the inclusion criteria. Postoperative neurological changes, mostly transient, were observed in 18 patients. Hypoesthesia in the ulnar side of the handwas observed in seven cases; neuropathic pain in five cases; allodynia in four cases, and hand motor loss in two cases. Conclusion Based on the results of the present case series, we conclude that there are few sequelae in the donor nerve territory compared with the benefit of the Oberlin technique on the recovery of elbow flexion after brachial plexus injuries.


Subject(s)
Postoperative Complications , Brachial Plexus/surgery , Brachial Plexus/injuries , Musculocutaneous Nerve/surgery , Medical Records , Retrospective Studies , Nerve Transfer/methods , Hypesthesia/complications
2.
Braz. dent. sci ; 21(1): 54-63, 2018. tab, ilus
Article in English | LILACS, BBO | ID: biblio-881852

ABSTRACT

Objective: The aim of this study was to evaluate the effect of pH and concentration of bleaching agents on the mineral content and surface morphology of human dental enamel for 14 days. Material and Methods: Eighty human central incisors were randomly divided into 8 groups (n=10): G1-7.5% hydrogen peroxide/ pH=9.0; G2­9.5% hydrogen peroxide/pH=9.0; G3- 7.5% hydrogen peroxide/pH=7.0; G4-9.5% hydrogen peroxide/pH=7.0; G5-10% carbamide peroxide/ pH=5.0; G6-16% carbamide peroxide/pH=5.0; G7- 37% phosphoric acid 15s (positive control); G8-no treatment (negative control). The mineral analysis of the bleaching gel collected was assessed by ICP-AES and surface morphology was observed by SEM. Results: Friedman and Dunn's statistical test demonstrated significant differences among the proposed treatments (p0.01). However, the latter groups showed significantly higher values as compared to groups G1, G2, G3 and G4 (p<0.01). Conclusion: Alteration in enamel mineral content may not be influenced by concentration when bleaching agents with the same pH are compared. The most apparent alterations in mineral content and surface morphology may be noted when more acidic products are used. The daily mineral content measurement may not be influenced by repeated applications of bleaching agents. (AU)


Objetivo: Este estudo avaliou o efeito do pH e da concentração de agentes clareadores no conteúdo mineral e na morfologia da superfície do esmalte dental humano durante 14 dias. Material e Métodos: Oitenta incisivos centrais humanos foram aleatoriamente divididos em 8 grupos (n = 10): G1-peróxido de hidrogênio 7.5% /pH = 9.0; G2 - peróxido de hidrogênio 9.5%/pH = 9,0; G3 - peróxido de hidrogênio 7.5%/pH = 7,0; G4-de peróxido de hidrogênio 9.5% / pH = 7,0; G5 - Peróxido de carbamida 10% / pH = 5.0; G6 - peróxido de carbamida 16%/pH = 5.0; G7- ácido fosfórico 37% (controle positivo); G8 - sem tratamento (controle negativo). A análise mineral do gel clareador coletado foi avaliada por ICP-AES e a morfologia da superfície foi observada por MEV. Resultados: Os testes estatísticos de Friedman e Dunn demonstraram diferenças significativas entre os tratamentos propostos (p<0,01). Nenhuma diferença significativa foi encontrada entre os grupos tratados com peróxido de hidrogênio (G1, G2, G3 e G4) ou entre os grupos G5, G6 e G7 (p>0,01), no entanto, os estes grupos apresentaram valores significativamente maiores em relação aos grupos G1, G2, G3 e G4 (p <0,01). Conclusão: Alterações no conteúdo mineral do esmalte não foram influenciadas pela concentração dos agentes clareadores quando os mesmos pH são comparados. As alterações mais significativas no conteúdo mineral e na morfologia da superfície foram notadas quando clareadores mais ácidos foram utilizados. A mensuração diária do conteúdo mineral não foi influenciada por repetidas aplicações de agentes clareadores. (AU)


Subject(s)
Bone Density , Demineralization , Dental Enamel , Hydrogen-Ion Concentration , Peroxides , Tooth Bleaching
3.
Braz. oral res. (Online) ; 31(supl.1): e57, Aug. 2017.
Article in English | LILACS | ID: biblio-889455

ABSTRACT

Abstract Bonding plays a major role in dentistry nowadays. Dental adhesives are used in association with composites to solve many restorative issues. However, the wide variety of bonding agents currently available makes it difficult for clinicians to choose the best alternative in terms of material and technique, especially when different clinical situations are considered. Moreover, although bonding agents allow for a more conservative restorative approach, achieving a durable adhesive interface remains a matter of concern, and this mainly due to degradation of the bonding complex in the challenging oral environment. This review aims to present strategies that are being used or those still in development which may help to prevent degradation. It is fundamental that professionals are aware of these strategies to counteract degradation as much as possible. None of them are efficient to completely solve this problem, but they certainly represent reasonable alternatives to increase the lifetime of adhesive restorations.


Subject(s)
Humans , Dental Bonding/methods , Dental Bonding/trends , Dental Cements/chemistry , Chlorhexidine/chemistry , Collagen/drug effects , Dental Restoration, Permanent/methods , Dental Restoration, Permanent/trends , Dentin/chemistry , Dentin/drug effects
4.
Biota Neotrop. (Online, Ed. ingl.) ; 17(4): e20170413, 2017. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1038845

ABSTRACT

Abstract Heliconius nattereri C. Felder & R. Felder, 1865 is an enigmatic and rarely collected species. Because of severe habitat reduction, the species is currently listed as endangered. We here report the confirmation of a northernmost population. This collection and further observations reported here add two more known localites to the distribution of the species. Two of the three confirmed locations are in protected areas. We worry that the northern population may be at great risk because it is not formally protected. We urge conservation efforts to preserve the local forests where the species is found.


Resumo Heliconius nattereri C. Felder & R. Felder, 1865 é uma espécies enigmática e raramente coletada. Em função de severa perda de habitat, a espécie encontra-se atualmente listada como ameaçada. Neste trabalho, relatamos a confirmação do registro de uma população no limite norte da distribuição da espécie. Nossas coletas e outras observações aqui relatadas adicionam dois novos locais para a distribuição da espécie. Duas das três localizações confirmadas encontram-se em áreas protegidas. Nos preocupa saber que a população aqui relatada pode estar em risco por não estar formalmente protegida. Esforços de conservação das florestas que abrigam esta espécie são urgentemente necessários.

5.
Ortho Sci., Orthod. sci. pract ; 9(34): 30-35, 2016.
Article in Portuguese | LILACS, BBO | ID: biblio-831174

ABSTRACT

São objetivos deste trabalho avaliar clínica e laboratorialmente a intensidade das forças liberadas por elastômeros em cadeia pré-estirados. A intensidade e o percentual de degradação das forças elásticas liberadas por duas marcas de elastômeros em cadeia (3M - 3MU e American Orthodontics - AO) foram avaliadas em solução de saliva artificial e no meio bucal. As forças liberadas durante a realização do experimento foram quantificadas através de uma máquina de ensaios de tração (EMIC). Todos os grupos apresentaram forças menores geradas pelos elastômeros em três semanas, quando comparadas com as respectivas forças iniciais. Houve uma grande variação das médias apresentadas em relação aos períodos de tempo intermediários avaliados para os dois meios e para as duas marcas testadas. No final de um período de 3 semanas, os valores médios das forças geradas pelos elastômeros da marca AO foram mais elevados do que os gerados por elastômeros da marca 3MU. Após o período de 3 semanas ambas as marcas de elastômeros geraram forças suficientes para produzir o movimento dentário.


The objective of this study was to evaluate clinically and in the laboratory the intensity of forces delivered by prestretched elastomeric chains. The intensity and percentage of force decay of two commercial brands of elastomeric chains, 3M Unitek (3MU) and American Orthodontics (AO), were evaluated in artificial saliva and in the oral environment. The forces generated during the experiment were quantified by means of a tensile testing machine (EMIC). All groups showed a reduction in the forces generated by the elastomers within a 3-week period compared with their respective initial (baseline) forces. There was a wide variation in the means achieved in those time periods in which the two environments and the two brands were assessed. At the end of a 3-week period, the mean values of the forces generated by AO elastomers were higher than those generated by 3MU elastomers. After the 3-week period both brands of elastomers still generated enough force to produce dental movement.


Subject(s)
Elastomers , Orthodontics , Tensile Strength
6.
Arq. bras. neurocir ; 33(1)mar. 2014. ilus
Article in Portuguese | LILACS | ID: lil-721663

ABSTRACT

A derivação ventriculoperitoneal (DVP) representa uma forma importante e comum de tratamento da hidrocefalia. Entretanto, pode ocorrer uma série de complicações durante a sua instalação ou por causa de seu mau funcionamento, como infecção, obstrução e hiperdrenagem liquórica. Nesse trabalho, descrevemos uma rara complicação em que um paciente submetido à DVP evoluiu com tetraparesia progressiva. Investigação posterior evidenciou hiperdrenagem da válvula, levando a diminuição do retorno venoso intracraniano, dilatação do plexo venoso epidural e consequente compressão medular no nível da junção bulbomedular. Após o diagnóstico, fizemos o ajuste no nível de desempenho da válvula, e o paciente evoluiu com melhora clínica. Concluímos que o conhecimento desse tipo de complicação associada à disfunção de DVP pode levar a um diagnóstico mais precoce e melhor resposta ao tratamento. O tratamento envolve a correção do fator causal, ou seja, a hiperdrenagem...


The ventriculoperitoneal shunt represents an important and common treatment of hydrocephalus. However, there may be a number of complications during installation or due to a malfunction, such as infection, obstruction and overdrainage. In this paper, we described a rare complication in a patient submitted to a shunt who evolved to progressive tetraparesis. Further investigation showed valve overdrainage, leading to a decrease in venous return, intracranial epidural venous plexus dilatation and consequent cord compression at cervicomedullary junction. After the diagnosis, we adjusted the level of performance of the valve and the patient clinically improved. We concluded that the knowledge of this kind of complication related to shunt dysfunction may take to an early diagnosis and a better treatment response. The treatment involves correcting the causative factor which is the overdrainage...


Subject(s)
Humans , Male , Adult , Ventriculoperitoneal Shunt/adverse effects , Hydrocephalus/complications , Spinal Cord Compression
7.
J. vasc. bras ; 11(3): 226-231, jul.-set. 2012. ilus
Article in Portuguese | LILACS | ID: lil-653563

ABSTRACT

As oclusões arteriais crônicas totais com forte componente cálcico são ainda nos dias atuais, um fator muitas vezes limitante para o tratamento endovascular devido à dificuldade em transpor estas lesões com fios-guia e cateteres habitualmente utilizados. Revisamos a literatura e descrevemos um caso de tratamento endovascular de uma oclusão total de artéria ilíaca externa, onde o uso de novos materiais desenvolvidos especificamente para o tratamento deste tipo de lesão foi determinante para o sucesso do caso.


Chronic arterial occlusions with great calcium component are usually a factor of limitation to endovascular treatment to the difficulty to transpose these lesions with guidewires and catheters commonly used. We reviewed the literature and described a case of endovascular treatment of a total occlusion of external iliac artery, where the use of new materials developed specifically to the treatment of such injuries was critical to the success of the case.


Subject(s)
Humans , Female , Adult , Arterial Occlusive Diseases/therapy , Arteriosclerosis/diagnosis , Diabetes Mellitus/diagnosis , Endovascular Procedures/history , Angiography/nursing , Anticoagulants/administration & dosage , Aspirin/administration & dosage , Balloon Occlusion , Simvastatin/administration & dosage
8.
Arq. bras. neurocir ; 30(3)set. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-613347

ABSTRACT

Objetivo: Os autores realizaram uma avaliação comparativa entre a abordagem anterior e posterior do nervo acessório para transferência nervosa para o nervo supraescapular. Método: Foram estudados pacientes submetidos à neurotização do nervo supraescapular utilizando como doador o nervo acessório, no período de janeiro de 2007 a janeiro de 2010. Os registros cirúrgicos foram avaliados para analisar as vantagens e desvantagens das duas formas de abordagem desses nervos na cirurgia. Foram avaliados os marcos anatômicos utilizados para a localização dos nervos durante a cirurgia e as dificuldades ocorridas nas duas formas de abordagem. Resultados: Foram estudados ao todo 29 pacientes, sendo que 22 deles foram abordados pela via anterior e sete por via posterior. A localização do nervo supraclavicular foi considerada mais fácil pela via posterior, enquanto a localização do nervo acessório foi feita mais rapidamente pela via anterior. Em nenhuma das cirurgias foi necessária a interposição de enxerto nervoso. Não ocorreram complicações cirúrgicas nas duas técnicas. Conclusão: A análise comparativa das duas abordagens cirúrgicas demonstra que a anatomia desses dois nervos é importante fator na dificuldade técnica apresentada na cirurgia. Novos estudos devem analisar se há uma melhora dos resultados funcionais com a abordagem pela via posterior.


Objective: The authors conducted a comparative evaluation between the previous approach and later transfer accessory nerve to nerve nervous supraescapular. Method: Patients undergoing the nerve supraescapular transfer to the accessory nerve, in the period January 2007 to January 2010 were studied. Surgical records were evaluated to analyze the advantages and disadvantages of the two ways to approach these nerves in surgery. The anatomical landmarks used for localization of nerves during surgery were evaluated and the difficulties that occurred in the two forms of approaches. Results: Were studied in all 29 patients, with 22 of these were addressed through anterior and 7 through posterior. The location of supraclavicular nerve was considered easier through posterior approach, while the localization of accessory nerve was made more quickly through anterior. In none of the surgeries were required the interposition graft nervous. Non-surgical complications occurred in two techniques. Conclusion: A comparative analysis of two forms of surgical approach demonstrates that knowledge of the anatomy of these two nerves is important factor in technical difficulty presented in surgery. New long-term studies should examine whether there is an improvement of the functional results with the approach through posterior.


Subject(s)
Humans , Male , Female , Nerve Transfer , Accessory Nerve/surgery , Brachial Plexus/surgery
9.
J. vasc. bras ; 10(3): 217-221, jul.-set. 2011. ilus
Article in Portuguese | LILACS | ID: lil-604465

ABSTRACT

A associação entre a síndrome de veia cava superior e uma dilatação aneurismática das artérias aorta e ilíacas não é comum. A abordagem de cada uma destas patologias pode ser efetuada através do modo convencional, com cirurgia aberta ou pela técnica endovascular. Neste trabalho, relatamos as duas modalidades de intervenção cirúrgica executadas e discutimos suas indicações e os resultados deste caso em particular.


The association between superior vena cava syndrome and an aorto-iliac aneurysm is not common. The approach to each of theses diseases can be either by the conventional way with open surgery or by endovascular techniques. We report the two methods of surgical intervention and discuss their indications and results in this particular case.


Subject(s)
Humans , Iliac Aneurysm/surgery , Vena Cava, Superior , Blood Vessel Prosthesis , Time Factors
10.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 23(2)maio-ago. 2011. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-601374

ABSTRACT

Introdução: Levando-se em conta que atualmente estão disponíveis aos ortodontistas diferentes materiais para colagem de acessórios ortodônticos e várias marcas comerciais de bráquetes, decidiu-se avaliar, por meio de ensaios mecânicos: 1) A capacidade de retenção, por meio de testes de tração, de bráquetes metálicos das marcas Ormco Orthodontics e Morelli Ortodontia; 2) A resistência adesiva de dois materiais para colagem: sistema adesivo ortodôntico Enlight (Resina Enlight com resina fluída Ortho Solo) e um sistema não específico para ortodontia, formado pela resina composta fotopolimerizável Charisma associada ao adesivo Single Bond; 3) Índice de Remanescente de Adesivo (IRA) presente nas superfícies dentárias após os testes de tração em microscopia ótica. Métodos: Foram utilizados sessenta primeiros pré-molares humanos superiores do lado direito, divididos aleatoriamente em quatro grupos de quinze dentes cada. Os testes de tração foram realizados em máquina de ensaios Instron. Resultados e Conclusão: De acordo com a metodologia empregada e após análise estatística através do programa GMC 2002 (Testes de Kruskal Wallis) e discussão dos resultados obtidos, pôde-se concluir que: os bráquetes Ormco Orthodontics colados com o sistema Enlight apresentaram os maiores valores de resistência à tração, seguidos pelos bráquetes Morelli Ortodontia colados com a mesma resina, bráquetes Ormco Orthodontics colados com a resina Charisma e, por último, bráquetes Morelli Ortodontia colados com resina Charisma. Em relação ao Índice de Remanescente de Adesivo, não houve diferença estatística entre os grupos analisados e a maior parte da resina ficou aderida ao esmalte dentário após as descolagens


Introduction: Taking into account that currently are available to orthodontists different systems for orthodontic bonding of accessories and various trademarks of brackets, we decided to evaluate, through mechanical tests: 1) The bond strength, through tensile tests, of two trademarks of metal brackets: Ormco Orthodontics (Glendora, CA) and Morelli Orthodontics (Sorocaba, SP), 2) The bond strength of two bonding systems: orthodontic adhesive Enlight (Ormco Orthodontics, Glendora, CA) and a system not specific to orthodontics, composed by the composite resin Charisma (Heraeus Kulzer) associated with the adhesive Single Bond (3M ESPE, Monrovia, USA), 3) Adhesive Remnant Index (ARI) in the tooth surfaces after the tensile tests in optical microscope. Methods: Sixty first human upper right premolars were used, all from the right side, which were divided into two groups of thirty teeth, one for each brand of bracket. Each of these has been divided into two groups, one for each composite resin, resulting in four groups of samples: Brackets Ormco Orthodontics (Glendora, CA) associated with Enlight and Ortho Solo (Ormco Orthodontics, Glendora, CA); brackets Ormco Orthodontics (Glendora, CA) associated with Charisma (Heraeus Kulzer) and adhesive Single Bond (3M ESPE); brackets Morelli Orthodontia (Sorocaba, SP) associated with Enlight and Ortho Solo (Ormco Orthodontics, Glendora, CA) and brackets Morelli Orthodontia (Sorocaba, SP) with Charisma (Heraeus Kulzer) and adhesive Single Bond (3M ESPE). The tests were performed in the Instron tensile testing machine. Results and Conclusion: According to the methodology employed and after statistical analysis using the program 2002 GMC (Kruskal Wallis tests) and discussion of the results, we could conclude that the Ormco Orthodontics brackets bonded with Enlight (Ormco Orthodontics) associated with Ortho Solo fluid resin (Ormco Orthodontics) had the highest values of tensile strength, followed by brackets Morelli Orthodontia bonded with the same resin, brackets Ormco Orthodontics bonded with Charisma resin (Heraeus Kulzer) associated with adhesive Single Bond (3M ESPE), and finally, brackets Morelli Orthodontia bonded with Charisma composite resin associated with Single Bond, which submitted the lowest values of tensile. For the Adhesive Remnant Index (ARI), there was no statistical difference between the groups analyzed and most of the composite resin was attached to the tooth enamel after the debonding


Subject(s)
Tensile Strength , Orthodontic Brackets , Dental Cements
11.
J. vasc. bras ; 10(1): 72-76, mar. 2011. ilus
Article in Portuguese | LILACS | ID: lil-587799

ABSTRACT

A Síndrome de May-Thurner é uma causa pouco comum de sinais e sintomas venosos relacionados ao membro inferior esquerdo. Esta síndrome é caracterizada pela compressão da veia ilíaca comum esquerda pela artéria ilíaca comum direita e, quando tal alteração anatômica causa sintomas que venham a prejudicar a qualidade de vida do paciente, existe a indicação de tratamento cirúrgico ou endovascular para correção desta alteração anatômica. Este artigo é o relato de um caso, no qual optou-se pelo tratamento endovascular com resultado satisfatório e as indicações, as nuances e os resultados esperados para esta técnica no tratamento da Síndrome de May-Thurner são discutidos. Foi concluído que, nesta síndrome, há eficácia do tratamento endovascular com melhora dos sintomas pela recanalização do sistema venoso, sem grandes riscos inerentes ao procedimento e com curto período de internação hospitalar.


May-Thurner Syndrome is an uncommon cause of venous symptoms and signs related to the left lower limb. It is characterized by compression of the left common iliac vein by the right common iliac artery and, when such anatomical change causes symptoms that may impair the patients' quality of life, surgical treatment is indicated. This article addresses a case of May-Thurner syndrome in which we opted for endovascular treatment with satisfactory outcome, as well as a discussion about indications, nuances, and expected results. We concluded that endovascular treatment is effective in treating this syndrome, for it resolves the symptoms by recanalization of the venous system with little risks during the procedure and with short hospital stay.


Subject(s)
Humans , Female , Adult , Vascular Diseases/surgery , Vascular Diseases/therapy , Lower Extremity/surgery , Iliac Vein/abnormalities , Angioplasty, Balloon/methods , Stents
12.
J. vasc. bras ; 9(4): 266-269, dez. 2010. ilus
Article in Portuguese | LILACS | ID: lil-578808

ABSTRACT

Os filtros de veia cava são utilizados para impedir a passagem de êmbolos dos membros inferiores para as artérias pulmonares e, normalmente, são colocadas imediatamente abaixo das veias renais. Em alguns casos, no entanto, existem dificuldades técnicas incomuns que devem ser superadas para tratar adequadamente alguns pacientes. Relatamos o caso de uma paciente em cujas veias ilíacas comuns foram implantados filtros de veia cava devido à baixa implantação das veias renais e da veia cava inferior curta.


Vena cava filters are used to prevent the passage of emboli from the lower limbs to the pulmonary arteries and normally are placed immediately below the renal veins. In some cases however there are unusual technical difficulties that must be overcome to properly treat some patients. We report a case of a patient in whose common iliac veins vena cava filters were deployed, due to the lower implantation of renal veins and a short inferior vena cava.


Subject(s)
Humans , Female , Vena Cava Filters , Vena Cava, Inferior , Venous Thrombosis
13.
Rev. Ciênc. Méd. Biol. (Impr.) ; 7(3): 305-309, set.-dez. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-545799

ABSTRACT

O tratamento odontológico não está isento de riscos. Acidentes e complicações podem estar associados aos vários tipos de procedimentos realizados pelo cirurgião dentista. Dentre as especialidades, a cirurgia bucomaxilofacial é aquela em que o profissional está mais exposto a encontrar complicações. As agulhas anestésicas conduzem a solução anestésica do tubete aos tecidos, levando à interrupção temporária na condução dos impulsos dolorosos. Nas primeiras décadas do século 20, eram utilizadas, para anestesia local, agulhas rígidas e não descartáveis, o que proporcionava uma incidência muito grande de fraturas de agulha durante bloqueios anestésicos. Com a evolução tecnológica, foram desenvolvidas as agulhas descartáveis, fabricadas com aço inoxidável flexível, permitindo, assim, que esse tipo de complicação se tornasse rara. Atualmente, as razões para esse acidente são variadas e podem estar associadas a falhas na fabricação da agulha, a movimentação súbita do paciente durante a punção, ou a erros de técnica profissional, como a inserção de toda a haste da agulha no tecido-alvo, dobra da haste da agulha ou a sua reutilização excessiva, o que provoca a fadiga do metal. Este artigo se propõe a apresentar um relato de caso de fratura de agulha anestésica tratado no serviço de cirurgia e traumatologia bucomaxilofacial do Hospital Santo Antônio das Obras Sociais Irmã Dulce.


Subject(s)
Humans , Female , Intraoperative Complications , Needles , Anesthesia , Surgery, Oral , Dental Instruments , Oral Surgical Procedures
14.
Neotrop. entomol ; 37(3): 247-252, May-June 2008. ilus, graf
Article in English | LILACS | ID: lil-486560

ABSTRACT

Trichomes reduce herbivore attack on plants by physically and/or chemically inhibiting movement or other activities. Despite evidence that herbivores are negatively affected by trichomes there also reports of insect counter-adaptations that circumvent the plantÆs defense. This paper reports on a study that investigated the likely mechanisms employed by larvae of the nymphalid butterfly, Heliconius charithonia (L.), that allow it to feed on a host that is presumably protected by hooked trichomes (Passiflora lobata (Killip) Hutch). Evidence were gathered using data from direct observations of larval movement and behavior, faeces analysis, scanning electron microscopy of plant surface and experimental analysis of larval movement on plants with and without trichomes (manually removed). The latter involved a comparison with a non specialist congener, Heliconius pachinus Salvin. Observations showed that H. charithonia larvae are capable of freeing themselves from entrapment on trichome tips by physical force. Moreover, wandering larvae lay silk mats on the trichomes and remove their tips by biting. In fact, trichome tips were found in the faeces. Experimental removal of trichomes aided in the movement of the non specialist but had no noticeable effect on the specialist larvae. These results support the suggestion that trichomes are capable of deterring a non specialist herbivore (H. pachinus). The precise mechanisms that allow the success of H. charithonia are not known, but I suggest that a blend of behavioral as well as physical resistance mechanisms is involved. Future studies should ascertain whether larval integument provides physical resistance to trichomes.


Apesar de as evidências mostrarem que herbívoros são negativamente afetados pelos tricomas, há também relatos de contra-adaptações que sobrepujam as defesas das plantas. Este estudo busca os prováveis mecanismos usados pelas larvas da borboleta ninfalídea Heliconius charithonia (L.) que permitem que elas se alimentem de uma planta hospedeira que é, presumivelmente, protegida por tricomas uncinados (curvados) (Passiflora lobata (Killip) Hutch.). Para isso realizou-se observação direta de movimento e comportamento da larva, análise de fezes, microscopia eletrônica de varredura da superfície foliar e análise experimental do movimento de larvas em plantas com e sem tricomas (removidos manualmente). O experimento foi feito comparando o comportamento dessas larvas com o de larvas de um não-especialista, Heliconius pachinus Salvin. As larvas de H. charithonia são capazes de se desvencilhar do aprisionamento pelos tricomas usando força física. Além disso, ao movimentar-se, a larva espalha fios de seda sobre os tricomas e retira suas pontas com as mandíbulas. De fato, pontas de tricoma foram encontradas nas fezes das larvas. A remoção experimental dos tricomas auxiliou o movimento da larva não-especialista, mas não teve efeitos notáveis sobre a larva especialista. Os resultados confirmam que os tricomas são capazes de deter um herbívoro não especializado (H. pachinus). Os exatos mecanismos responsáveis pelo sucesso de H. charithonia ainda são desconhecidos, mas sugere-se que a combinação de mecanismos comportamentais e de resistência física estejam envolvidos e estudos futuros necessitam verificar a possibilidade de resistência física no tegumento das larvas.


Subject(s)
Bees , Nesting Behavior
15.
Braz. oral res ; 22(2): 170-175, 2008. UCI, graf, tab
Article in English | LILACS, BBO | ID: biblio-874024

ABSTRACT

O Objetivo Deste estudo avaliar UM Foi Influência da simulação de Pressão intrapulpar Sobre a Eficácia da LigAção do etch e enxaguar etch à dentina e auto- adesivos . Oitenta molares Foram divididos em Grupos Humanos Oito , de De De acordo com o grau de permeabilidade De cada amostra , hum Por medido avaliar Aparelho par Uma condutividade hidráulica (Lp ). Assim , a permeabilidade média similar Foi Realizado em grupo CADA. Sistema UM Lavar etch Três e adesivos (Prime & Bond NT - PB, Single Bond -SB , e Excite - EX ) e de self- etch ( Clearfil SE Bond - SE) Foram utilizados , variando A presença OU Ausência de Pressão intrapulpar (IPP ) simulação de 15 cmH2O. DEPOIS DE Adesivo Procedimentos e restaurador Foram realizados , Como amostras armazenadas Por Foram em água destilada 24 horas a 37 º C, e Levado Para a Resistência à tração (TBS) de testes. A análise da Fratura Foi realizada UM Utilizando microscópicos de luz em Uma Ampliação de 40 X . Os Dados, obtidos em MPa, submetidos Foram AO teste de Kruskal -Wallis (a = 0,05). Os resultados revelaram que A TBS de SB e EX Foi significativamente reduzida em simulação IPP, diferindo da TBS de PB e SE. Além disso , SE OS obtidos maiores valores de Resistência de União Na Presença do IPP. realizados Concluiu- se que Uma simulação IPP PoDE influenciar Uma Resistência de União de Sistemas adesivos à dentina e determinado considerados devem Ser QUANDO estudos in vitro , São Paulo (


Subject(s)
Humans , Young Adult , Adult , Adhesives , Hydrostatic Pressure , Materials Testing , Microscopy, Electron, Scanning , Molar , Surface Properties , Tensile Strength , Young Adult
16.
Braz. oral res ; 22(2): 170-175, 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-485958

ABSTRACT

The purpose of this study was to evaluate the influence of intrapulpal pressure simulation on the bonding effectiveness of etch & rinse and self-etch adhesives to dentin. Eighty sound human molars were distributed into eight groups, according to the permeability level of each sample, measured by an apparatus to assess hydraulic conductance (Lp). Thus, a similar mean permeability was achieved in each group. Three etch & rinse adhesives (Prime & Bond NT - PB, Single Bond -SB, and Excite - EX) and one self-etch system (Clearfil SE Bond - SE) were employed, varying the presence or absence of an intrapulpal pressure (IPP) simulation of 15 cmH2O. After adhesive and restorative procedures were carried out, the samples were stored in distilled water for 24 hours at 37°C, and taken for tensile bond strength (TBS) testing. Fracture analysis was performed using a light microscope at 40 X magnification. The data, obtained in MPa, were then submitted to the Kruskal-Wallis test ( a = 0.05). The results revealed that the TBS of SB and EX was significantly reduced under IPP simulation, differing from the TBS of PB and SE. Moreover, SE obtained the highest bond strength values in the presence of IPP. It could be concluded that IPP simulation can influence the bond strength of certain adhesive systems to dentin and should be considered when in vitro studies are conducted.


Subject(s)
Adult , Humans , Young Adult , Composite Resins/chemistry , Dental Bonding , Dentin Permeability , Dental Pulp/physiology , Dentin-Bonding Agents/chemistry , Dentin/physiology , Adhesives , Bisphenol A-Glycidyl Methacrylate/chemistry , Dentin/ultrastructure , Dentinal Fluid/physiology , Hydrostatic Pressure , Materials Testing , Microscopy, Electron, Scanning , Molar , Statistics, Nonparametric , Surface Properties , Tensile Strength , Young Adult
17.
São Paulo; s.n; 2006. 128 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-453530

ABSTRACT

A atual tendência ao desenvolvimento de uma odontologia minimamente invasiva tem sido responsável pela introdução de instrumentos e técnicas alternativas de preparo cavitário. Porém, tais tecnologias deveriam não somente preencher os requisitos de uma odontologia conservadora, mas também preparar as paredes da cavidade para o tratamento restaurador adesivo subseqüente. Assim, o objetivo deste estudo foi testar a hipótese nula de que: 1) tanto técnicas convencionais quanto técnicas alternativas de preparo cavitário são capazes de produzir um substrato dentinário receptivo à adesão de sistemas autocondicionantes; e 2) A efetividade adesiva de sistemas autocondicionantes não é influenciada pela interposição da camada de esfregaço. Cem molares humanos íntegros foram aleatoriamente divididos em 20 grupos de acordo com o adesivo e a técnica ou instrumento utilizado. Superfícies planas de dentina média oclusal foram preparadas com instrumento rotatório diamantado convencional (IR); fratura; instrumento rotatório CVD (IRCVD); instrumento ultra-sônico CVD (IUCVD); e laser de Er,Cr:YSGG .Um adesivo condicione-e-lave (Optibond FL/OB) e três autocondicionantes (Adper Prompt L-Pop/AP, Clearfil SE Bond/SE e Clearfil S3 Bond/S3) foram empregados. Os espécimes foram construídos com o compósito Z100/3M ESPE. A resist6encia adesiva foi determinada por meio de teste de microtração após 24 h de estocagem em água a 37oC. Amostras adicionais foram processadas para análise em MEV quanto às características morfológicas apresentas após o preparo das superfícies dentinárias em cada caso. O teste de Kruskal-Wallis (p<0,05) determinou que os grupos preparados com IRCVD, IUCVD e laser apresentaram menores valores de resistência adesiva quando comparados aos grupos controle (IR e fratura). Além disso, os adesivos de menor acidez (SE e S3) foram mais eficientes quando aplicados em dentina fraturada. Concluiu-se que o uso de ...


Subject(s)
Dental Cavity Preparation , Dentin-Bonding Agents , Dentistry, Operative , Lasers , Microscopy, Electron, Scanning , Smear Layer , Tensile Strength , Ultrasonics
18.
Neotrop. entomol ; 34(6): 1007-1008, Nov.-Dec. 2005.
Article in English | LILACS | ID: lil-451303

ABSTRACT

New occurrences for two Heliconius Kluk species are reported for sites in inland Bahia, Brazil. New inland sites are reported for Heliconius sara (Fabricius), a species normally found at coastal regions. To our knowledge, Heliconius besckei Ménétriés, a species restricted to cool mountain habitats, is reported for Northeastern Brazil for the first time.


Novas ocorrências para duas espécies de Heliconius Kluk são registradas para áreas no interior da Bahia. Novas áreas interioranas para Heliconius sara (Fabricius), uma espécie encontrada na costa, são apresentadas. Este é, provavelmente, o primeiro relato de Heliconius besckei Ménétriés para o Nordeste brasileiro.


Subject(s)
Hepatocyte Growth Factor , Insecta , Residence Characteristics , Trees
19.
Rev. odontol. Univ. Cid. Sao Paulo ; 17(3): 229-234, set.-dez. 2005. tab
Article in Portuguese | LILACS, BBO | ID: lil-550247

ABSTRACT

Introdução: Neste trabalho, estudou-se a força de união da resina composta com diferentes materiais estéticos indiretos. Método: Para tanto, foram estabelecidos 10 grupos constituídos por 10 amostras cada um: Grupo 1 (fargis), 2 (Cesead II), 3 (Solidex) e 4 (Artglass), todas resinas laboratoriais jateadas com Al203 de 501/4m, condicionadas com H3(P0)4 a 37% por 1 minuto e cobertas com silano (Monobond-S); Grupos 5 (D'sign), 6 (Noritake) e 7 (Heraceram), de porcelanas feldspáticas jateadas com Al203' condicionadas com HF a 10% por 4 minutos e cobertas com silano; e Grupos 8 (Cergogold), 9 (Empress) e 10 (Empress 2), de porcelanas injetáveis jateadas com Al203 condicionadas com HF por 2 minutos (G8), 1 minuto (G9) ou 20 segundos (G10) e cobertas com silano. Após aplicação do adesivo Excite, as amostras foram preparadas para teste de tração com a resina composta Inten-S, sendo então armazenadas em água destilada a 37°C por 48h previamente ao ensaio mecânico. Resultados: Os dados obtidos foram submetidos ao teste ANOVA de um critério e teste de Tukey (p<0,05), observando-se as seguintes médias em MPa: 27,31 :t 1.23 (G1); 23,78:t 2.88 (G2); 22,62:t 3.38 (G3); 28,77 :t 2.65 (G4); 28,96 :t 2.01 (G5); 36,45 :t 0.83 (G6); 26,77 :t 7.20 (G7); 26,25 :t 1.39 (G8); 34,96 :t 4.17 (G9);29,23 :t 3.16 (G 10). Conclusão: Conclui-se que a classificação dos materiais em termos de resistência adesiva foi determinada pelas marcas comerciais estudadas, sendo que as porcelanas Noritake e Empress atingiram os maiores valores de resistência adesiva.


Introduction: This study evaluated the bond strength of composite resin for several indirect aesthetic materiaIs. Method: Ten groups consisting of 10 specimens each were formed and classified as follows: Groups 1 (fargis), 2 (Cesead II), 3 (Solidex) and 4 (Artglass), consisted of laboratory resins that were sandblasted with Al203 (50µm), etched with 37% phosphoric acid for 1 minute and silanized (Monobond-S); Groups 5 (D'sign), 6 (Noritake) and 7 (Heraceram), composed of feldspathic porcelains sandblasted with Al203 (50µm), etched with 10% hydrofluoric acid for 4 minutes and silanized; and Groups 8 (Cergogold), 9 (Empress) and 10 (Empress 2), consisted of pressable ceramics that were sandblasted with Al2O3 (50µm), etched with 10% hydrofluoric acid for the following periods: 2 minutes (G8), 1 minute (G9) and 20 seconds (G 10) and silanized. After bonding (Excite) and restorative (Inten-S) procedures, the samples were stored in distilled water at 37°C for 48h and submitted to tensile strength testing. Result: The obtained data were statistically analyzed by one way ANOVA and Tuckey tests, and the following means (MPa) were observed: 27.31 :t 1.23 (G1); 23.78 :t 2.88 (G2); 22.62 :t 3.38 (G3); 28.77 :t 2.65 (G4); 28.96 :t 2.01 (G5); 36.45 :t 0.83 (G6); 26.77 :t 7.20 (G7); 26.25 :t 1.39 (G8); 34.96 :t 4.17 (G9); 29.23 :t 3.16 (G 10). Conclusion: It was found that differences in trademarks should be taken into account when ranking materiaIs with respect to bond strengths. The ceramic materiaIs Noritake and Empress attained the highest bond strength values.


Subject(s)
Dental Porcelain , Composite Resins , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL